Theory: | Current Level Relay |
---|---|
Phase: | 1 |
Electricity Type: | AC/DC |
Type: | Electric Parameter Relay |
Package: | Original Package |
Mounting Type: | DIN-Rail or Plug-in |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
Place of Origin | Switzerland |
Brand Name | Carlo gavazzi |
Model Number | DIB01CB235A |
Mounting type | DIN-rail or Plug-in |
Description | Current level relay |
Application | Industrial Instrument |
Product Name | DIB01CB235A |
Certificate | CE-UR-CSA |
Package | Original Package |
Condition | Original 100% |
Warranty | 1 Year |
Type | DIB01CB235A |
Application | Experience |
Shipping By | DHL\UPS\Fedex\EMS\HK Post |
MOQ | 1 Piece |
DIB01 and PIB01 are precise TRMS AC/DC over or under current (selectable by DIP switch) monitoring relays. Direct measuring or through current transformer. Owing to the built-in latch function, the ON-position of the relay output can be maintained. Inhibit function can be used to avoid relay operation when not desired (maintenance, transitions). The LED's indicate the state of the alarm and the output relay. Through the built-in shunt it is possible to mon itor loads up to 10 A AC/DC.
• TRMS AC/DC over or under current monitoring relay
• Current measuring through internal shunt
• Selection of measuring range by DIP-switches
• Measuring ranges from 0.1 mA to 10 A AC/DC
• Adjustable current on relative scale
• Adjustable hysteresis on relative scale
• Adjustable delay function (0.1 to 30 s)
• Programmable latching or inhibit at set level
• Output: 8 A SPDT relay N.D. or N.E. selectable
• For mounting on DIN-rail in accordance with DIN/EN/EC 60715 (DIB01) or plug-in module (PIB01)
• 22.5 mm Euronorm housing (DIB01) or 36 mm plug-in module (PIB01)
• LED indication for relay, alarm and power supply ON
• Galvanically separated power supply
DIB01 and PIB01 monitor both AC and DC over or under current through an internal shunt.
Example 1: (connection between termin als Z1, Y1 or 8, 9 - latching function enabled) The relay operates and latches in operating position when the measured value exceeds (or drops below) the set level for more than the set delay time. Provided that the current has dropped below (or has exceeded) the set point (see hysteresis setting), the relay releases when the interconnection between terminals Z1, Y1 or 8, 9 is interrupted or the power supply is interrupted as well. The red LED flashes until the delay time has expired or the measured value comes back to a non-alarm value (see hysteresis setting).
Example 2: (Stardard CT) (no connection between ter minals Z1, Y1 or 8, 9 - latch function disabled) The relay operates when the measured value exceeds (or drops below) the set level for more than the set delay time. It releases when the current drops below (or exceeds) the set level (see hysteresis setting) or when power supply is interrupted.
Note:
When the inhibit contact is opened, if the input signal is already in alarm position, the delay time needs to elapse before relay activation.